This is comprising of :-
1.        Power Supply (PSU) normally a 12 dc supply
2.        12 volt Keypad
3.        Break-Glass Unit
4.        12 volt dc Strike Lock
Strike Locks come in 2 forms.....
Fail-Safe (When the power is removed the lock opens) requires a constant 12v supply to keep the lock locked and removing the voltage unlocks the door.
Fail-Secure (When the power is removed the lock remains locked) requires no voltage to keep the lock locked and applying a voltage unlocks the door.


The 12 Psu  is fitted inside the building preferably above a ceiling or in a secure locked cupboard.

The PSU is powered off a 240v spur unit.

The existing lock Keeper for the door is removed and replaced with the 12 volt strike lock. Using the now internally fitted egress button to release the door from the inside. There is also an additional Break-Glass unit fitted to over ride the egress button or lock should either fail to operate door ass normal normally

The keypad is fitted outside the door at a convenient height as to allow ease of use to disabled and able bodied personnel

If this system is fitted it is recommended it be wired through a Fire Alarm  relay.